RO Plants Industrial Commercial

RO Plant 500 LPH

Description Features
Technology Membrane Based, (Model: 4040), Qty- 2 no.
Electricity 2.2 KW/Ac-220V/440V, 50Hz
Filtration Suspended Solids, Chemical Impurities, Bacteria like Cryptosporidium, Pseudomonas, and Pathogens e-coli.
Pre Filtration Media & Activated Carbon Filter and Micron Filter
Post Filtration Ultra Violet (UV) Optional
Design to Work TDS up to 3000 ppm, Hardness 1000 mg/I
Operating Mode Automatic
Monitoring Accessories Display Panel, Inbuilt TDS meter, Pressure Gauges, Flow Meters etc.

RO Plant 1000 LPH, Standard Model

Description Features
Technology Membrane Based, (Size: 40 x 40), Qty -4 Nos.
Electricity 3.8 KW/AC-220 – 440v, 50Hz
Filtration Suspended Solids, Chemical Impurities, Bacteria like Cryptosporidium, Pseudomonas, and Pathogens e-coli.
Pre Filtration Sand Filter, Activated Carbon Filter, Filters 5 & 10 Micron
RO Piping UPVC / SS 304 Optional
Post Filtration ULTRA VIOLET (UV) Optional
Pumps, Skid SS 304
Design to Work TDS up to 2000 ppm, Hardness 1000 ppm
Operating Mode Automatic + Manual
Monitoring Accessories Display/ DOL Panel, Pressure Gauges, Flow Meters etc.

RO Plant 250 LPH

Description Features
Technology Membrane Based, (Model: 4040)
Electricity 1520 W / Ac-220V/440V, 50Hz
Filtration Suspended Solids, Chemical Impurities, Bacteria like Cryptosporidium, Pseudomonas, and Pathogens e-coli.
Pre Filtration Media & Activated Carbon Filter and Micron Filter
Post Filtration Ultra Violet (UV) Optional
Design to Work TDS up to 3000 ppm, Hardness 1000 mg/I
Operating Mode Automatic
Accessories Display Panel, Inbuilt TDS meter, Pressure Gauges, Flow Meters etc.

RO Plant 150 LPH

Description Features
Technology Membrane Based, (Model: 4021)
Electricity 1260W/Ac-220V, 50Hz
Filtration Suspended Solids, Chemical Impurities, Bacteria like Cryptosporidium, Pseudomonas, and Pathogens e-coli.
Pre Filtration Media & Activated Carbon Filter and Micron Filter
Post Filtration Ultra Violet (UV) Optional
Design to Work TDS up to 2000 ppm, Hardness 1000 mg/I
Operating Mode Automatic
Accessories Display Panel, Inbuilt TDS meter, Pressure Gauges, Flow Meters etc.

RO Plant 100 LPH

Description Features
Technology Membrane Based, (Size : 30×12)
Electricity 400W/ Ac-220v/ 50Hz
Filtration Chemical Impurities, bacteria like Cryptosporidium, Pseudomonas, and Pathogens e-coli.
Filtration Stage 4 Stages(2 Pre filter + 1Post Filter)
Design to Work TDS up to 1000 ppm, Hardness 500 mg/I
Operating Mode Automatic + Manual

RO Plant 250 LPH

Description Features
Technology Membrane Based, (Model: 4040)
Electricity 1520 W / Ac-220V/440V, 50Hz
Filtration Suspended Solids, Chemical Impurities, Bacteria like Cryptosporidium, Pseudomonas, and Pathogens e-coli.
Pre Filtration Media & Activated Carbon Filter and Micron Filter
Post Filtration Ultra Violet (UV) Optional
Design to Work TDS up to 3000 ppm, Hardness 1000 mg/I
Operating Mode Automatic
Accessories Display Panel, Inbuilt TDS meter, Pressure Gauges, Flow Meters etc.

 

RO Plant 500 LPH

Description Features
Technology Membrane Based, (Model: 4040), Qty- 2 no.
Electricity 2.2 KW/Ac-220V/440V, 50Hz
Filtration Suspended Solids, Chemical Impurities, Bacteria like Cryptosporidium, Pseudomonas, and Pathogens e-coli.
Pre Filtration Media & Activated Carbon Filter and Micron Filter
Post Filtration Ultra Violet (UV) Optional
Design to Work TDS up to 3000 ppm, Hardness 1000 mg/I
Operating Mode Automatic
Monitoring Accessories Display Panel, Inbuilt TDS meter, Pressure Gauges, Flow Meters etc.

 

RO Plant 1000 LPH, Standard Model

Description Features
Technology Membrane Based, (Size: 40 x 40), Qty -4 Nos.
Electricity 3.8 KW/AC-220 – 440v, 50Hz
Filtration Suspended Solids, Chemical Impurities, Bacteria like Cryptosporidium, Pseudomonas, and Pathogens e-coli.
Pre Filtration Sand Filter, Activated Carbon Filter, Filters 5 & 10 Micron
RO Piping UPVC / SS 304 Optional
Post Filtration ULTRA VIOLET (UV) Optional
Pumps, Skid SS 304
Design to Work TDS up to 2000 ppm, Hardness 1000 ppm
Operating Mode Automatic + Manual
Monitoring Accessories Display/ DOL Panel, Pressure Gauges, Flow Meters etc.

RO Plant 1000 LPH, Deluxe Model

Description Features
Technology Membrane Based, (Size: 40 x 40), Qty 4 Nos. (Dow, USA)
Electricity 3.5 KW/AC-220 – 440v, 50Hz
Filtration Suspended Solids, Chemical Impurities, Bacteria like Cryptosporidium, Pseudomonas, and Pathogens e-coli.
Pre Filtration Sand Filter, Activated Carbon Filter, Filters 5 & 10 Micron
RO Piping UPVC / SS 304 Optional
Post Filtration ULTRA VIOLET (UV) Optional
Pumps, Skid SS 304
Design to Work TDS up to 4000 ppm, Hardness 1000 ppm
Operating Mode Automatic + Manual
Monitoring Accessories Display/ DOL Panel, Pressure Gauges, Flow Meters etc.

RO Plant 2000 to 4000 LPH

Description Features
Technology Membrane Based, (Model: 8040)
Electricity 4- 6 KW / 440V
Filtration Suspended Solids, Chemical Impurities, Bacteria like Cryptosporidium, Pseudomonas, and Pathogens e-coli.
Pre Filtration Sand Filter, Activated Carbon Filter, Micron Filter-5 &10
Post Filtration Ozonator / UV (Optional)
Design to Work TDS up to 4000 ppm, Hardness 1000 mg/I
Operating Mode Automatic + Manual
Accessories Digital / DOL , Pressure Gauges, Flow Meters etc.

RO Plant 5000,6000 and 8000 LPH

Description Features
Technology Membrane Based, (Size: 8040)
Electricity 6KW/440v
Filtration Suspended Solids, Chemical Impurities, Bacteria like Cryptosporidium, Pseudomonas, and Pathogens e-coli.
Pre Filtration Sand Filter, Activated Carbon Filter, Micron Filter-5 &10
Post Filtration Ozonator / UV (Optinal)
Design to Work TDS up to 4000 ppm, Hardness 1000mg/I
Operating Mode Automatic + Manual
Monitoring Accessories MMIC Panel, Pressure Gauges, Flow Meters etc.

RO Plant 10000 LPH

Description Features
Technology Membrane Based, (Size: 8040)
Electricity 6KW/440v
Filtration Suspended Solids, Chemical Impurities, Bacteria like Cryptosporidium, Pseudomonas, and Pathogens e-coli.
Pre Filtration Sand Filter, Activated Carbon Filter, Micron Filter-5 &10
Post Filtration Ozonator / UV (Optinal)
Design to Work TDS up to 4000 ppm, Hardness 1000 mg/I
Operating Mode Automatic + Manual
Monitoring Accessories MMIC Panel, Pressure Gauges, Flow Meters etc.

Commercial RO Plant

Description Features
Technology Membrane Based, (Size : 18×12)
Electricity 40W/ Ac-220v/ 50Hz
Filtration Chemical Impurities, bacteria like Cryptosporidium, Pseudomonas, and Pathogens e-coli.
Filtration Stage 6 Stages(3 Prefilter+2 Post Filter)
Design to Work TDS up to 1000 ppm, Hardness 700 mg/I
Operating Mode Automatic
Description Features
Technology Membrane Based, (Size : 18×12)
Electricity 80W/ Ac-220v/ 50Hz
Filtration Chemical Impurities, bacteria like Cryptosporidium, Pseudomonas, and Pathogens e-coli.
Filtration Stage 6 Stages(4 Pre filter + 1Post Filter)
Design to Work TDS up to 1000 ppm, Hardness 700 mg/I
Operating Mode Automatic + Manual